How to Define Acceptance Criteria for a Constant Force Spring

A drawing that specifies only “constant force: X N” leaves three questions open: where in the stroke to measure, which direction to measure in, and what range counts as a pass. Agree on these before approving the sample, then use the same criteria for the first production lot.
1. Define the working stroke and test setup
Define zero using a physical reference, such as the installed rest position. Record any initial extension, the working stroke and the positions where readings will be taken. If starting force matters, list it as a separate requirement.
Specify whether you are testing the spring on an agreed fixture or measuring force at the operating point of the complete assembly. Record the applicable fixture or assembly revision and where the gauge attaches. Keep the force measured at the handle separate from the spring’s own force reading.
2. Specify extension, retraction, or both
Specify extension for force measured while pulling out and retraction for force measured on the return stroke. If both matter, record them separately at the same agreed positions and define limits for each direction as needed. Agree on test speed and whether readings are taken during motion or after stopping.
3. Define what passes at each point and across the stroke
If every point must fall within the force band, say so explicitly. An average can hide an out-of-limit reading. If force consistency also matters, set a separate limit on the difference between the highest and lowest readings in the same direction. For a requirement that applies throughout the working stroke, specify a force-versus-travel trace and the interval to review. Spot readings establish compliance only at the measured points.
4. Carry the criteria into first-lot inspection
Record the part number, drawing revision, lot number, fixture or assembly revision, and readings for each sample. Agree on sample quantity, the lot acceptance rule, and what happens if a reading falls outside the limit. Record installed fit or return checks separately from spring force acceptance.
Example inspection clause
Test part ___, drawing Rev ___, on fixture ___, with zero defined at ___. Measure force during ___ at travel positions ___ using the agreed speed and reading method ___. Each required reading must fall between ___ and ___ N. If stroke variation is specified, evaluate it over ___ in the ___ direction against the agreed limit of ___ N. Sample ___ units per lot and apply the agreed lot acceptance rule ___.
If you already have a test procedure or inspection specification for your constant force spring, send it to us with the relevant drawing revision. We’ll review your requirements with you and test the spring against the agreed procedure and acceptance criteria.

One Comment